Pharmaceutical manufacturing requires analytical technologies that provide reliable chemical information while
integrating seamlessly into industrial quality control workflows. Beyond research applications, production
environments demand robustness, reproducibility, automation capability, and regulatory compliance support.
The chemical identity, spatial distribution, and solid-state form of active pharmaceutical ingredients (APIs)
directly influence product performance, stability, and patient safety. Even minor variations in polymorphic form or
blend homogeneity can affect therapeutic efficacy.
Confocal
Raman microscopy combines molecular specificity with high spatial resolution and non-destructive analysis. The
microscopy and software provides features that support institutional and regulatory processes at an operational level.
Functions such as multi‑user role management, internal calibration routines, automated reporting, and reproducibility
features help maintain consistent procedures and clear data handling. The
witec360 platform further extends these capabilities into industrial environments by enabling fast confocal
Raman imaging, spectral acquisition and guided evaluation, supporting structured workflows and reliable analytical
execution.

Raman setup in a pharmaceutical environment.
Technology Overview
Raman spectroscopy is based on the inelastic scattering of monochromatic laser light. During interaction with
molecular vibrations, a small fraction of scattered photons undergoes a characteristic frequency shift. This shift
reflects the molecular structure and provides a highly specific chemical fingerprint.


When combined with confocal microscopy, Raman spectroscopy enables spatially resolved chemical imaging in two and
three dimensions. This allows both identification and localization of compounds within complex pharmaceutical
formulations.
Advantages over other methods
- No sample preparation required.
- Non-destructive and contact-free.
- High chemical specificity and spatial resolution.
Key features of witec360 systems
- True confocal Raman imaging for 3D chemical mapping.
- Rapid data acquisition through highly sensitive detectors.
- Possibility to combine with AFM or further correlative technologies for multimodal analysis.
The
witec360 platform is built on a true confocal optical design, ensuring high lateral and axial resolution while
minimizing background signals, such as fluorescence. This architecture is particularly advantageous for heterogeneous
samples such as coated tablets, granulates, or multilayer systems.
Hexalight is the innovative spectrometer at the heart of the
witec360 Raman microscopes. Its pioneering, lens‑based design eliminates mirrors and sets new benchmarks for
throughput and spectral versatility, offering exceptional broadband performance. Hexalight’s outstanding sensitivity
helps accelerate workflows and significantly reduce integration times, which enables large-area mapping and screening
applications suitable for industrial fail analysis and quality control.
TrueSurface technology allows Raman measurements on uneven or curved sample surfaces without refocusing artifacts.
Automated z-scanning enables volumetric chemical imaging and depth profiling without destructive cross-sectioning.
The integrated software supports automated spectral clustering, chemical segmentation, and advanced visualization
options, while standardized data export ensures fully traceable workflows.
Applications in Industrial Pharmaceutical Workflows
Raman microscopy addresses critical analytical questions in pharmaceutical research as well as in product and process
development. Within industrial environments, reproducibility and automation are as important as analytical
performance.
Polymorphism analysis enables reliable differentiation of crystalline forms of APIs, supporting solid-state stability
studies and batch verification. API distribution mapping provides quantitative insight into blend homogeneity and dose
uniformity. Contamination analysis enables rapid identification of foreign particles. In addition, Raman spectroscopy
supports Process Analytical Technology (PAT) strategies for atline measurement approaches. Standardized measurement
routines reduce operator dependency and increase batch-to-batch reproducibility.
Typical Pharmaceutical Applications and Workflow Integration
| Analytical Task |
Industrial Relevance |
witec360 Workflow Integration |
| Polymorphism analysis |
Verification of solid-state stability and batch consistency |
High spectral resolution, automated phase differentiation |
| API distribution in tablets |
Dose uniformity and blend homogeneity control |
Automated 2D/3D mapping, cluster-based segmentation |
| Contamination analysis |
Root-cause analysis in QC for raw materials |
Automated particle routines, spectral library matching |
| Coating homogeneity |
Controlled release performance |
TrueSurface, depth profiling, volumetric imaging |
Industrial Measurement Examples
API Distribution in a Pharmaceutical Tablet
A tablet containing one API and multiple excipients was analyzed using confocal Raman imaging on the
witec360 platform. Surface mapping was performed with a lateral resolution of approximately 300 nm. Subsequent
depth profiling achieved an axial resolution of approximately 900 nm.
Automated cluster analysis enabled objective segmentation of chemically distinct regions. The resulting chemical maps
visualize the spatial distribution of API and excipients and verify the blend homogeneity. Deviations can be detected
at early stages of production, enabling corrective actions.

Chemical Raman map of tablet showing API and excipient distribution.
Polymorphic Distribution of Acetylsalicylic Acid (ASA)
Using high spectral resolution and confocal imaging, different polymorphic forms of ASA were identified and spatially
localized within a single tablet. The Hexalight spectrometer design ensures sufficient sensitivity and spectral
resolution to resolve subtle spectral differences between crystalline phases.
Automated spectral classification supports rapid polymorph differentiation, strengthening stability assessment and
batch validation workflows.

Raman polymorph map of ASA showing spatial phase distribution.
3D Coating Analysis and Depth Profiling
Three-dimensional Raman imaging enables non-destructive analysis of coated tablets. Z-stack acquisition combined with
automated focus control (TrueSurface) that allows accurate determination of coating thickness, surface morphology and
internal API distribution.
This volumetric approach provides detailed insight into multilayer systems and supports optimization of coating
processes without destructive cross-sectioning.


Raman depth profile of coated tablet.
Advantages for Industrial Pharmaceutical Environments
The
witec360 systems are to support both, fundamental research tasks and industrial, repetitive operations through
robust optical architecture, high-throughput spectroscopy, and automated measurement protocols.
The combination of high chemical specificity, submicron spatial resolution, and a compliance-oriented ecosystem -
spanning hardware, software, and application support - makes Raman microscopy suitable not only for research
laboratories but also for regulated quality control settings.
Conclusion
The
witec360 Raman imaging platform provides a comprehensive analytical solution for industrial pharmaceutical
material characterization. From polymorph identification to automated API mapping and three-dimensional coating
analysis, the system integrates high-resolution chemical imaging into standardized quality control workflows.
By combining analytical performance with workflow compatibility and automation, Raman microscopy becomes a key